Product Description

Product Description

 

The maximum opening value is a circular hole or a tapered hole with a keyway.

Main applications:

DWZ disc eddy current brake is mainly used as load in loading dynamometer equipment. it is experimental apparatus which can measure the dynamic mechanical properties, especially in dynamic loading test whose power value is small or tiny, also can be treated as suction power devices of other dynamic devices.

DW series disc eddy current dynamometer is, is that add device for measuring torque and rotational speed on DWZ series disc eddy current brake, it is experimental apparatus which can measure the dynamic mechnical properties, especial in dynamic loading test whose power value is small or tiny.

CW eddy current brake as a load is mainly used to measure the mechanical characteristics of inspection equipment, it and other control instrument (including loading apparatus, torque speed sensor and torque power acquisition instrument etc.) can be composed of eddy current dynamometer can be used for performance testing of the internal combustion engine, motor, gas turbine, automobile and its dynamic mechanical components, compared with other power measuring device, the CW series power measuring device has the advantages of reliability, high stability and practicability.

Eddy current brake/dynamometer Rated Power Rated torque Rated speed Maximum rotational speed Turning inertia Maximum excitation voltage Maximum excitation Current Cooling water pressure Flow of the cooling water
DWZ/DW-0.75 0.75 5 2000-2600 16000 0.002 80 3 0.1~0.3 1
DWZ/DW-3 3 10 2000-2600 14000 0.003 80 3 0.1~0.3 2
DWZ/DW-6 6 25 2000-2600 14000 0.003 80 3 0.1~0.3 3
DWZ/DW-10 10 50 2000-2600 13000 0.01 80 3 0.1~0.3 4.5
DWZ/DW-16 16 70 2000-2600 13000 0.02 80 3.5 0.1~0.3 6.5
DWZ/DW-25 25 120 2000-2600 11000 0.05 80 3.5 0.1~0.3 15
DWZ/DW-40 40 160 2000-2600 10000 0.1 90 4 0.1~0.3 25
DWZ/DW-63 63 250 2000-2600 9000 0.18 90 4 0.1~0.3 45
DWZ/DW-100 100 400 2000-2600 8500 0.32 120 4 0.1~0.3 60
DWZ/DW-160 160 600 2000-2600 8000 0.52 120 5 0.1~0.3 100
DWZ/DW-250 250 1100 2000-2600 7000 1.8 150 5 0.2~0.4 180
DWZ/DW-300 300 1600 2000-2600 6000 2.7 150 5 0.2~0.4 210
DWZ/DW-400 400 2200 2000-2600 5000 3.6 180 10 0.2~0.4 300
DWZ/DW-630 630 3600 2000-2600 5000 5.3 180 10 0.2~0.4 450

 

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

drive coupling

What are the Temperature and Speed Limits for Different Drive Coupling Types?

The temperature and speed limits for different drive coupling types vary based on their design, materials, and intended applications. Here are some general guidelines for temperature and speed limits for common drive coupling types:

  • Elastomeric Couplings: Elastomeric couplings, which use rubber or elastomer elements, typically have temperature limits ranging from -40°C to 120°C (-40°F to 248°F). The speed limits for elastomeric couplings are generally up to 5000 RPM, but this can vary depending on the coupling size and design.
  • Grid Couplings: Grid couplings are designed to handle higher torque and speed requirements. They often have temperature limits between -20°C to 100°C (-4°F to 212°F). The speed limits for grid couplings can range from 5000 to 8000 RPM, depending on the coupling size and grid material.
  • Gear Couplings: Gear couplings are known for their high torque capacity and can operate at higher temperatures. Their temperature limits typically range from -20°C to 150°C (-4°F to 302°F). The speed limits for gear couplings can vary widely based on the coupling’s size and design, with some models capable of operating at speeds up to 10,000 RPM or higher.
  • Chain Couplings: Chain couplings are suitable for heavy-duty applications. They often have temperature limits between -20°C to 150°C (-4°F to 302°F) depending on the chain material. The speed limits for chain couplings can range from 1500 to 6000 RPM, depending on the chain type and size.

It’s essential to consider the operating environment, load conditions, and coupling material when determining the suitable temperature and speed limits for a specific application. Exceeding the recommended limits can lead to premature wear, reduced performance, and potential coupling failure.

Manufacturers of drive couplings provide detailed specifications and operating guidelines for their products. It’s crucial to consult the manufacturer’s documentation to ensure that the selected coupling is suitable for the intended application and operating conditions.

drive coupling

Is it Possible to Replace a Drive Coupling Without Professional Help?

Replacing a drive coupling without professional help is possible in some cases, but it is not recommended for everyone. The complexity of the task and the level of expertise required depend on the specific coupling type, the application, and the individual’s mechanical skills. Here are some considerations:

  • Simple Couplings: Some drive couplings are relatively simple and may be easy to replace, especially if they are accessible and don’t require specialized tools or equipment.
  • Mechanical Aptitude: Individuals with a good understanding of mechanical systems, tools, and procedures may feel more confident in attempting to replace a drive coupling on their own.
  • Manufacturer’s Instructions: If the manufacturer provides detailed instructions for coupling replacement, individuals with mechanical knowledge may be able to follow the steps and perform the replacement.
  • Risk of Damage: Incorrect installation of the coupling can lead to damage, misalignment, or premature failure. If unsure about the procedure, it is best to seek professional assistance to avoid costly mistakes.
  • Specialized Couplings: Some drive couplings, especially those used in complex industrial applications, may require specialized knowledge and tools for replacement.
  • Safety Concerns: Working with rotating machinery can be hazardous. If not properly handled, injuries can occur. Professional technicians are trained to handle such tasks safely.
  • Warranty and Liability: Attempting a DIY replacement may void any warranty on the coupling. Additionally, if the replacement causes damage or accidents, it could lead to liability issues.

If you have doubts about your ability to replace the drive coupling correctly or if it requires specialized knowledge and equipment, it is best to seek professional help. Experienced technicians have the expertise and tools to perform the replacement safely and efficiently, ensuring the proper functioning of the power transmission system.

For those with the necessary skills and experience, following the manufacturer’s instructions and safety guidelines is essential when attempting to replace a drive coupling on their own.

drive coupling

What is a Drive Coupling and its Role in Mechanical Power Transmission?

A drive coupling is a mechanical device used to connect two shafts in a power transmission system. Its primary role is to transmit torque from one shaft to another while accommodating misalignments and absorbing shocks and vibrations. Drive couplings play a crucial role in transferring mechanical power efficiently and reliably between rotating components in various industrial applications.

The key features and functions of drive couplings include:

  • Power Transmission: Drive couplings are designed to transmit mechanical power from the driving shaft to the driven shaft. As the driving shaft rotates, the coupling transfers the torque to the driven shaft, causing it to rotate and perform the intended task, such as driving a pump, conveyor, or generator.
  • Misalignment Compensation: In real-world applications, shafts may not be perfectly aligned due to factors such as assembly tolerances, thermal expansion, or equipment settling. Drive couplings can accommodate angular, parallel, and axial misalignments between the shafts, ensuring smooth power transmission even under misaligned conditions. This capability helps to reduce stress on connected machinery and enhances overall system reliability.
  • Shock and Vibration Damping: During operation, rotating equipment often experiences shocks and vibrations that can be harmful to the machinery and reduce its lifespan. Drive couplings with elastomeric or flexible elements can dampen these shocks and vibrations, providing a smoother power transmission and protecting the connected equipment from excessive loads.
  • Overload Protection: In some applications, sudden torque spikes or overloads may occur due to process changes or unforeseen events. Drive couplings equipped with torque-limiting features can protect the machinery from damage by disengaging or slipping when the torque exceeds a predetermined threshold.
  • Reduced Maintenance: Drive couplings that require minimal maintenance contribute to the overall efficiency of the power transmission system. By reducing the need for frequent maintenance and lubrication, downtime is minimized, leading to increased productivity and cost savings.
  • Compact and Versatile Design: Drive couplings are available in various designs and sizes to accommodate different application requirements. Their compact and versatile design makes them suitable for a wide range of industries and machinery types, from small motors in automotive systems to large industrial drives in mining and manufacturing processes.

Overall, drive couplings are essential components in mechanical power transmission systems. Their ability to efficiently transfer torque while compensating for misalignments and absorbing shocks ensures reliable and long-lasting operation of rotating equipment in various industries.